ePrivacy and GPDR Cookie Consent by Cookie Consent

What to read after Introduction to Power System Protection?

Hello there! I go by the name Robo Ratel, your very own AI librarian, and I'm excited to assist you in discovering your next fantastic read after "Introduction to Power System Protection" by Dr. Hedaya Alasooly! πŸ˜‰ Simply click on the button below, and witness what I have discovered for you.

Exciting news! I've found some fantastic books for you! πŸ“šβœ¨ Check below to see your tailored recommendations. Happy reading! πŸ“–πŸ˜Š

Introduction to Power System Protection

Dr. Hedaya Alasooly

Technology & Engineering / Power Resources / Electrical

Power system protection systems have three basic components: Instrument transformers, Relays, Circuit breakers

The function of the CT is to reproduce in its secondary winding a current I' that is proportional to the primary current I. The CT converts primary currents in the kiloamp range to secondary currents in the 0–5 ampere range for convenience of measurement.

The function of the relay is to discriminate between normal operation and fault conditions. The OC relay in Figure 2 has an operating coil, which is connected to the CT secondary winding, and a set of contacts. When |I'| exceeds a specified ''pickup'' value, the operating coil causes the normally open contacts to close. When the relay contacts close, the trip coil of the circuit breaker is energized, which then causes the circuit breaker to open.

System-protection components have the following design criteria:

  • Reliability: Operate dependably when fault conditions occur, even after remaining idle for months or years. Failure to do so may result in costly damages.
  • Selectivity: Avoid unnecessary, false trips.
  • Speed: Operate rapidly to minimize fault duration and equipment damage. Any intentional time delays should be precise.
  • Economy: Provide maximum protection at minimum cost.
  • Simplicity: Minimize protection equipment and circuitry.

Since it is impossible to satisfy all these criteria simultaneously, compromises must be made in system protection.

The book consists from the following sections:

  1. Chapter 1: Power System Faults:
  2. Chapter 2: Instrument Transformers.
  3. Chapter 3: Overcurrent and Earth Fault Protection Relays.
  4. Chapter 4: Radial System Protection.
  5. Chapter 5: Zones of Protection.
  6. Chapter 6: Differential Relays.
  7. Chapter 7: Distance Relays.
  8. Chapter 8: Transformer Protection.
  9. Chapter 9: Generator Protection.
  10. Chapter 10: Busbar Protection.
  11. Chapter 11: Circuit Breakers.
  12. Chapter 12: Fuses.
  13. Chapter 13: References.
Do you want to read this book? 😳
Buy it now!

Are you curious to discover the likelihood of your enjoyment of "Introduction to Power System Protection" by Dr. Hedaya Alasooly? Allow me to assist you! However, to better understand your reading preferences, it would greatly help if you could rate at least two books.